Emerson Fisher's C483-24 Series 3 in. Internal Valve is a double-flange unit designed for special bobtail truck applications where the pump must be lowered to clear the truck frame or other obstacles. A special shear section in the body permits the lower section of the valve to shear off in the event of an accident, leaving the critical shutoff parts within the tank.
Flanged valves provide a sturdy and compact means of directly mounting a pump or piping connection. Special stud bolts, weakened with a groove on the outside diameter, are furnished with the valves to permit the pump or piping to shear off in the event of an accident, leaving the valve intact. A build-in excess flow valve reduces the chance of uncontrolled product discharge when flow exceeds the rated flow capacity.
Features
- Patented Rapid Equalization Bleed Area
- Unique Serviceability Features
- Excess Flow Closure
- Back Check Feature
- Spring loaded polytetrafluoroethylene (PTFE) stub shaft packing
- PTFE wear pads Rulon® Bushings at critical wear points
- Manual, Cable, or Air Open/Close valve actuators
- Thermal Fusible links or plugs melt at 212 to 220°F / 100 to 104°C and allow valve closure in the event of a fire at the valve
Specifications
- Series: C483-24 - Double Flange
- Type: Flange x Flange
- Inlet: 3 in. CL300 RF Flange - Modified Flange (4.62-inch / 117 mm diameter bore)
- Outlet: 3 in. CL300 RF Flange
- Body Material: Steel
- Maximum Allowable Inlet Pressure: 400 psig / 27.6 bar WOG
- Temperature Capabilities: -20° to 150°F (-29° to 66°C)
- Certifications: UL, CRN
Warning
Warning: Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. Fisher® equipment must be installed, operated and maintained in accordance with federal, state and local codes and Emerson Process Management Regulator Technologies, Inc. (Emerson™) instructions. The installation in most states must also comply with NFPA No. 58 and ANSI Standard K61.1. Only personnel trained in the proper procedures, codes, standards and regulations of the LP-Gas industry should install and service this equipment. The internal valve must be closed except during product transfer. A line break downstream of a pump may not actuate the excess flow valve. If any break occurs in the system or if the excess flow valve closes, the system should be shut down immediately.
Downloads
Instruction Manual (PDF Download)