Emerson Fisher C484-24 Series 3 in. ASME Single Flanged Jet Bleed Steel Internal Valve

SKU:
Please choose an option below
Manufacturer:
Emerson Fisher
Size:
3 in.
Material:
Steel
Pressure:
400 PSI
Weight:
18.00 LBS
$3,926.46
Adding to cart… The item has been added

Emerson Fisher's C484-24 Series 3 in. Internal Valve is a single flange unit widely used on bobtail and transport trucks for compact means of direct pump connection to the valve outlet. Also used on in-line installations.

Flanged valves provide a sturdy and compact means of directly mounting a pump or piping connection. Special stud bolts, weakened with a groove on the outside diameter, are furnished with the valves to permit the pump or piping to shear off in the event of an accident, leaving the valve intact. A build-in excess flow valve reduces the chance of uncontrolled product discharge when flow exceeds the rated flow capacity.

Features

  • Patented Rapid Equalization Bleed Area
  • Unique Serviceability Features
  • Excess Flow Closure
  • Back Check Feature
  • Spring loaded polytetrafluoroethylene (PTFE) stub shaft packing
  • PTFE wear pads Rulon® Bushings at critical wear points
  • Manual, Cable, or Air Open/Close valve actuators
  • Thermal Fusible links or plugs melt at 212 to 220°F / 100 to 104°C and allow valve closure in the event of a fire at the valve

Specifications

  • Series: C483-24
  • Type: Flange x Flange
  • Inlet: 3 in. CL300 RF Flange - Modified Flange (4.62-inch / 117 mm diameter bore)
  • Outlet: 3 in. CL300 RF Flange
  • Body Material: Steel
  • Maximum Allowable Inlet Pressure: 400 psig / 27.6 bar WOG
  • Temperature Capabilities: -20° to 150°F (-29° to 66°C)
  • Certifications: UL, CRN

Warning

Warning: Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. Fisher® equipment must be installed, operated and maintained in accordance with federal, state and local codes and Emerson Process Management Regulator Technologies, Inc. (Emerson™) instructions. The installation in most states must also comply with NFPA No. 58 and ANSI Standard K61.1. Only personnel trained in the proper procedures, codes, standards and regulations of the LP-Gas industry should install and service this equipment. The internal valve must be closed except during product transfer. A line break downstream of a pump may not actuate the excess flow valve. If any break occurs in the system or if the excess flow valve closes, the system should be shut down immediately.

Downloads

Instruction Manual (PDF Download)