null Skip to main content

Flowline EchoPod® DL14 Ultrasonic Multi-Function Liquid Level Sensor, 1 in. NPT, 4.1 ft. Range

SKU:
FLWDL1400
Manufacturer:
Flowline
Size:
1 in. Male NPT
Product Type:
Ultrasonic Liquid Level Sensor
Material:
PVDF
Weight:
0.40 LBS
$426.94
Adding to cart… The item has been added
EchoPod® DL14 general purpose ultrasonic mulit-function liquid level sensor with relay control provides continuous level measurement up to 49.2 in./ 4.1 ft. (1.25 m) range with a 4-20 mA signal output and four relays. The relay can be configured for alarm, automatic fill or empty functions. The level sensor is suited for small tanks with non-foaming, non-condensing or high vapor media such as chemicals, oil, water and wastewater. Applications include chemical feed, IBC, drum, skid or machine and small waste sumps.

Features

  • Level measurement, switch and control functions up to 49.2 in./ 4.1 ft. (1.25 m)
  • Narrow 2 in. beam width and short 2 in. dead band optimized for small tanks
  • PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
  • Automatic temperature compensation provides accurate measurement
  • 4 Programmable relays for switch, pump or valve control and fail-safety:
      (1) Pump or Valve with (3) Alarms
      (2) Pumps lead-lag with (2) alarms
      (2) Pumps duplexing with (2) alarms
      (4) Independent switch point alarms

Specifications

  • 1 in. (2.54 cm) NPT
  • Range: 49.2 in./4.1 ft. (1.25 m).
  • Accuracy: ±0.125 % range
  • Resolution: 0.019 in. (0.5 mm)
  • Dead band: 2 in. (5 cm)
  • Beam width: 2 in. (5 cm)
  • Contact fail-safe: Power loss, hold last, power on, open, close or hold last
  • Pressure: 30 PSI (2 bar)
  • Configuration: WebCal® PC, Windows®, USB 2.0
  • Supply Voltage: 24V DC (loop)
  • Max Consumption: 0.5 W
  • Loop resistance: 400 ohms max
  • Signal output: 4-20mA, two-wire
  • Signal invert: 4-20mA or 20-4 mA
  • Loop fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
  • Temp comp: Automatic
  • Enclosure rating Type 6: encapsulated, corrosion resistant & submersible
  • General purpose classification
  • Cable: 48 in. (1.2 m) 9-conductor, shielded style
  • PVDF transducer
  • Process temperature: 20° to 140° F (-7° to 60° C)
  • Ambient temp: -31° to 140° F (-35° to 60° C)
  • Viton® mount gasket
  • cFMus Approved
  • Complies to CE, RoHS