null Skip to main content

Liquid Controls LectroCount LCR-II Electronic Meter Register - Gallons

SKU:
LCR2EGG
Manufacturer:
Liquid Controls
Weight:
10.00 LBS
$3,284.08
Adding to cart… The item has been added

The Liquid Controls LectroCount LCR-II is a microprocessor-based electronic meter register that can be used for Weights & Measures approved custody transfer actions in mobile or fixed installations. The LCR-II can control a meter system as a stand-alone unit, or it can be used as a slave to a host contoller such as a process controller or an in-cab data management system.

Features

  • Weights & Measures custody transfer (product delivery and ticket generation)
  • Metrological data collection
  • Four product calibrations
  • Multi-point and Single-point calibration
  • Printed delivery, shift, and diagnostic tickets
  • Delivery quantity and totalizer
  • Security settings
  • Two auxiliary outputs (settings include: On, Off, On During Delivery, Monitor Flow Rate, Toggle Flowrate, and Flow Direction)
  • No-flow timer
  • RS232/RS485 communication
  • Electronic temperature volume compensation (ETVC)
  • Electronic presetting by volume
  • Electronic valve control
  • Electronic air or vapor elimination
  • 10-digit totalizer
  • Two control buttons for accessing and adjusting programmable data
  • NEMA 4X enclosure
  • -40 to 158 °F (-40 to 70 °C) temperature range
  • Available in Class I, Div 1 or Div 2 enclosure, Groups C & D
  • Easy-to-use RUN, STOP, PRINT, SHIFT PRINT red rotary selector switch
  • Hinged door for easy access to internal connections
  • One closure connection point with Weights & Measures sealable captive fastener
  • Compatible with most flowmeters (accepts input from PD, Amplified Turbine, Electromagnetic and Mass flowmeters)

Specifications

  • Materials of Construction: Aluminum Alloy ADC12 Corro-Coat PE 74-141 Polyester Powder Coat
  • Weight: 8.4 lbs (3.8 kg)
  • Display Elements: Liquid Crystal Display (LCD)
  • Cable Entry: ½ in. NPT (5); ¾ in. NPT (2)
  • Temperature Rating: -40 to 158 °F (-40 to 70 °C)
  • Input Voltage: 9 to 28 VDC, 4.5 A Maximum (including solenoid valves)
  • Pulse Output: 5 to 28 V Peak to Peak, 7500 Hz Maximum
  • Scale Pulse Output: 150 mA Sinking Capability
  • Electrical Protection: 5 A Fuse
  • Communications: RS-232: EIA-232E Standard; RS-485: SAE J1708 Standard
  • Auxiliary 1 Output: 1 A Sinking Capability
  • Auxiliary 2 Output: 150 mA Sinking Capability
  • Solenoid 1 Output: 10.2 to 27.2 VDC; 1 A Maximum
  • Solenoid 2 Output: 10.2 to 27.2 VDC; 1 A Maximum
  • Solenoid 3 Output: 10.2 to 27.2 VDC; 1 A Maximum
  • Optical Sensor: +10 to +28 VDC; 0.5 A Maximum
  • RTD Temperature Probe: 4 Wire Platinum Sensor; 100 Ω Resistance at 0 ºC; 138.5 Ω Resistance at 100 ºC
  • Remote Electronic Display: 1 A Sinking Capability