The Earth-Rite® FIBC system validates and monitors the resistance of Type C FIBC bags ensuring that the conductive elements of the bag are capable of dissipating electrostatic charges in compliance with IEC 61340-4-4 “Standard test methods for specific applications – Electrostatic classification of flexible intermediate bulk containers (FIBC)” and NFPA 77 “Recommended Practice on Static Electricity”.
The Earth-Rite FIBC system can be installed and setup to ensure that operators ground the bag before filling or emptying operations are started. During the bag filling / emptying process the Earth-Rite FIBC system continuously monitors the resistance of the bag so that if it rises above the recommended level of ohms (10 meg-ohm) this dangerous situation can be indicated to operators and the process halted, either manually or via the system’s pair of NO/NC volt free contacts. This feature ensures the generation and accumulation of static charges on the bag is stopped eliminating the risk of an electrostatic spark discharge.
Note: Several configurations available! Please call for more information.
Features
- Attention Grabbing LEDs: Three green LEDs continuously pulse informing operators that the FIBC bag to be protected from static discharges is correctly grounded - When the system is not in use, or when it detects the resistance in the static dissipative loop is higher than 1 x 10⁷ or 1 x 10⁸ Ohms a red LED illuminates the indicator panel located in the static dissipative GRP indicator station
- Continuous Ground Loop Monitoring: Monitors the resistance of the static dissipative loop through the FIBC bag back to the Earth-Rite FIBC via the plant earth grounding point - If the system detects that resistance in the loop is higher than 1 x 10⁷ohms, it engages a pair of output contacts
- Two Volt Free Output Contacts: The primary contact can interlock with electro-mechanical devices or PLC systems to shutdown the flow of product - The secondary contact can interface with attention grabbing audible alarms or strobe lights to provide an extra degree of safety over the hazard
- Easy Installation: Simple to mount enclosures complemented by straightforward cabling and PCB system wiring - Flexible hazardous area enclosure location options with separate IS monitoring / indicator and Power supply PCBs. Power supply PCB can run off both 240 V and 110 V mains / line supply and 24 V / 12 V DC voltage supply
Specifications
- Power Supply & Monitoring Unit
- Power Supply (AC version): 108/125V or 216/250 V AC, 50-60 Hz 12 V or 24 V DC
- Power Rating: 10 watt
- Ambient Temperature Range: -13°C to +131°C
- Ingress protection: Type 4X (IP 66)
- Construction: Carbon-Loaded GRP
- Monitoring Circuit: Intrinsically safe
- Operational Series Ground Resistance: ≤ 1 x 10⁷ or 1 x 10⁸ Ohms
- Output Relay Contacts Rating: 2 dry contacts; 250 V AC, 5 A, 500 VA max resistive; 30 V DC, 2 A, 60 W max resistive
- Cable Entries: 7 x M20 (4 x plugged)
- Junction Box/Stowage Point
- Enclosure Material: GRP with carbon loading
- Terminals: 2 x AWG #14 conductor capacity
- Stowage Device: Insulated 0.19 in. diameter pin
- Cable Entries: 1 x M20
- Clamp Cable Connection: Quick Connect
- Grounding Clamp
- Clamp Design: 1 pole with single stainless steel contact
- Body: Stainless Steel (SS 304)
- Certification: Ex II 1 GD T6
- Spiral Cable
- Cable: Blue Cen-Stat Hytrel sheath (Static dissipative, chemical & abrasion resistant)
- Cable: Orange Cen-Stat Hytrel sheath (Static dissipative, chemical & abrasion resistant)
- Conductors: 1 x AWG #12 steel
- Length: 5 meters extended, 1 meter unextended
Downloads
FIBC Static Grounding Protection Datasheet (PDF Download)
FIBC Static Grounding Protection Application Spotlight (PDF Download)