Remanufactured Dual Flat iMeter (001-048015 / 009-048015) for Wayne Vista/Ovation pumps
Features
- Inspected for defects to ensure the unit is rebuildable
- Completely disassembled and cleaned
- Individual parts inspected for wear and damage
- All O-rings, gaskets, and seals are replaced
- Valve seat surfaces ground and precision lapped
- 100% of remanufactured units are thoroughly tested
- Meters tested with several hundred gallons before calibration
- Meters calibrated to + - cubic inch on fast and slow flow
- Meters pressurized to ensure no leaks